Este é um estudo de caso simples, OLT Datacom não estabelecia conexão com Radius
Checado:
Usuário e Senha – OK
Server Radius Up – OK
aaa authentication-order [ local radius ]
aaa user admin
password PASSWORD
group admin
!
aaa server radius radius1
host 192.168.0.1
authentication
accounting
shared-secret PASSWORD
!
Verificado que haviam várias interfaces L3, e apesar de apenas uma delas ter IP, e com a rota default configurada, ainda sim não funcionava.
olt(config)# show interface l3
interface l3 vlan99
description gerencia-wan
lower-layer-if vlan 201
ipv4 address 192.168.1.1
!
interface l3 vlan362
description servico-1
lower-layer-if vlan 362
!
interface l3 vlan363
description servico-2
lower-layer-if vlan 363
!
interface l3 vlan388
description servico-3
lower-layer-if vlan 388
!
interface l3 vlan389
description servico-4
lower-layer-if vlan 389
!
Consultando log
olt# show log tail
2025-12-10 13:55:48.817 : 1/1 : %AAA-REMOTE_AUTHENTICATION_TIMEOUT : authenticator-app[16821] : User [renanadmin]: All Radius servers unavailable.
2025-12-10 13:55:48.859 : 1/1 : %AAA-CONNECTION_FAILED : pam-app[16817] : User [renanadmin]: Connection from host localhost failed. Protocol console.
Solução:
Informar a interface de origem de conexão (mesmo existindo apenas uma com IP e as outras não)
ou
Remover as interfaces l3 sem IP (o que faz sentido porque não tem utilidade, alguém pode ter esquecido de remover) e não usar “source interface …”
aaa server radius radius1
host 192.168.0.1
authentication
accounting
shared-secret PASSWORD
source interface l3-vlan99
!